SAQA All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source.
SOUTH AFRICAN QUALIFICATIONS AUTHORITY 
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: 

Install under-surface wireways and draw in conductors 
SAQA US ID UNIT STANDARD TITLE
119834  Install under-surface wireways and draw in conductors 
ORIGINATOR
SGB Electrical Engineering & Construction 
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY
-  
FIELD SUBFIELD
Field 12 - Physical Planning and Construction Electrical Infrastructure Construction 
ABET BAND UNIT STANDARD TYPE PRE-2009 NQF LEVEL NQF LEVEL CREDITS
Undefined  Regular  Level 1  NQF Level 01 
REGISTRATION STATUS REGISTRATION START DATE REGISTRATION END DATE SAQA DECISION NUMBER
Passed the End Date -
Status was "Reregistered" 
2018-07-01  2023-06-30  SAQA 06120/18 
LAST DATE FOR ENROLMENT LAST DATE FOR ACHIEVEMENT
2024-06-30   2027-06-30  

In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise.  

This unit standard does not replace any other unit standard and is not replaced by any other unit standard. 

PURPOSE OF THE UNIT STANDARD 
This unit standard is for persons in the Energy Sector.

A person credited with this unit standard will be capable of:
  • Installing under-surface wireways
  • Drawing in of conductors into wireways

    This unit standard will contribute to the full development of the learner within the energy sector by providing recognition, further mobility and portability of knowledge within the energy sector. The skills, knowledge and understanding demonstrated within this unit standard are essential for social and economic transformation and upliftment within the energy sector environment. 

  • LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING 
    It is assumed that learners are competent in the following:
  • Selecting, usage and care of relevant tools and equipment
  • Communication at ABET Level 3
  • Mathematical Literacy ABET Level 3 

  • UNIT STANDARD RANGE 
    Statutory requirements includes but is not limited to:
  • Relevant sections of OHS Act
  • Relevant SANS specifications
  • Local authority requirements
  • Manufacturers specifications
  • Worksite procedures

    Preparation includes but is not limited to:
  • Measuring and marking off and cutting of wireway lengths
  • Bending of wireways

    Equipment and tools include but is not limited to:
  • Scaffolding and ladders, power tools cutting disks, hand tools, pipe bending springs, hickeys, pipe vices, pipe cutters and reamers

    Wireways are limited to:
  • Conduit - flexible, metal, pvc 

  • Specific Outcomes and Assessment Criteria: 

    SPECIFIC OUTCOME 1 
    Plan work task. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Job instructions are interpreted to determine a sequence of operation according to standard procedures. 

    ASSESSMENT CRITERION 2 
    Task procedures and requirements are planned for the job including type and quantity of tools and materials lists according to job instructions. 

    ASSESSMENT CRITERION 3 
    Appropriate tools, equipment and materials are selected, checked and organised to meet the requirements of the activity. 

    ASSESSMENT CRITERION 4 
    Basic wireways layout is determined in accordance with job requirements. 

    ASSESSMENT CRITERION 5 
    Appropriate personal protective equipment (PPE) is selected in accordance with the statutory requirements. 

    SPECIFIC OUTCOME 2 
    Install under-surface wireways. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Wireways route are marked off according to given instructions. 

    ASSESSMENT CRITERION 2 
    Correct personal protective equipment is selected and used according to statutory requirements. 

    ASSESSMENT CRITERION 3 
    Correct tools are selected, inspected and used for cutting and chasing. 

    ASSESSMENT CRITERION 4 
    Codes of practice with respect to cutting and chasing depths are applied according to conduit and box specifications. 

    ASSESSMENT CRITERION 5 
    Walls and floors are cut and chased according to marked layout. 

    ASSESSMENT CRITERION 6 
    Safety regulations and procedures relevant to cutting and chasing are applied at all times. 

    ASSESSMENT CRITERION 7 
    Wireways are installed and supported into the cut out slot. 

    SPECIFIC OUTCOME 3 
    Complete task. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Tools are cleaned and stored on completion of the task according to worksite procedure. 

    ASSESSMENT CRITERION 2 
    Worksite is rehabilitated to acceptable condition. 

    ASSESSMENT CRITERION 3 
    Excess and unused material is cleaned and stored and debris is dispose of according to worksite procedure and environmental requirements. 

    SPECIFIC OUTCOME 4 
    Draw in conductors in wireways. 
    OUTCOME RANGE 
    Conductors exclude overhead lines. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Different types and sizes of conductors are identified as per labels on wire packaging. 

    ASSESSMENT CRITERION 2 
    Safety regulations and procedures relevant to installing conductors are applied at all times. 

    ASSESSMENT CRITERION 3 
    Correct drawing in methods for conductors are used according to instructions. 

    ASSESSMENT CRITERION 4 
    Colour coding for installing conductors is applied as per job instruction. 

    ASSESSMENT CRITERION 5 
    The relevant tools and equipment used for installing conductors are used correctly. 

    ASSESSMENT CRITERION 6 
    Housekeeping practices are applied on completion of task. 


    UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS 
  • Anyone assessing a learner against this unit standard must be registered as an assessor with the relevant ETQA.
  • Any institution offering learning that will enable achievement of this unit standard must be accredited as a provider through the relevant ETQA.
  • Moderation of assessment will be overseen by the relevant ETQA according to the moderation guidelines in the relevant qualification and the agreed ETQA procedures. 

  • UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE 
    Knowledge that will help me understand and that I will be able to explain:
  • Interpretation of basic layout drawings/documentation and electrical symbols.
  • Knowledge of purpose of different types of wireways.
  • Knowledge of wireways preparation techniques.
  • Knowledge of appropriate mounting/securing methods for wireways.
  • Practical application of relevant SANS pertaining to installing wireways and conductors.
  • Safety regulations relevant to installing wireways and conductors. 

  • UNIT STANDARD DEVELOPMENTAL OUTCOME 
    N/A 

    UNIT STANDARD LINKAGES 
    N/A 


    Critical Cross-field Outcomes (CCFO): 

    UNIT STANDARD CCFO IDENTIFYING 
    Identify and solve problems (deviations from statutory requirements are identified, reported and rectified). 

    UNIT STANDARD CCFO WORKING 
    Work effectively with others (affected parties are liased with and informed). 

    UNIT STANDARD CCFO ORGANISING 
    Organise and manage oneself (plan, select, organise work tasks). 

    UNIT STANDARD CCFO COLLECTING 
    Collect, organise and critically evaluate information (worksite preparation). 

    UNIT STANDARD CCFO COMMUNICATING 
    Communicate (affected parties are liased with and informed). 

    UNIT STANDARD ASSESSOR CRITERIA 
    N/A 

    REREGISTRATION HISTORY 
    As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. 

    UNIT STANDARD NOTES 
    Supplementary Information:

    Specified requirements:

    Specified requirements include legal and legislative specific requirements and are contained in one or more of the following documents:
  • SANS codes of practice
  • OHS Act , No 85 of 1993
  • Manufacturers' specifications and procedures 

  • QUALIFICATIONS UTILISING THIS UNIT STANDARD: 
      ID QUALIFICATION TITLE PRE-2009 NQF LEVEL NQF LEVEL STATUS END DATE PRIMARY OR DELEGATED QA FUNCTIONARY
    Elective  49753   General Education and Training Certificate: General Technical Practice  Level 1  NQF Level 01  Passed the End Date -
    Status was "Reregistered" 
    2023-06-30  EWSETA 


    PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: 
    This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here.
     
    1. KGWEBISWANO SUPPLIES & SERVICES 
    2. TECHNICAL INTEGRATED SOLUTIONS (PTY) LTD 



    All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source.