SAQA All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source.
SOUTH AFRICAN QUALIFICATIONS AUTHORITY 
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: 

Install in-situ reinforced and non-reinforced liquid based 
SAQA US ID UNIT STANDARD TITLE
262668  Install in-situ reinforced and non-reinforced liquid based 
ORIGINATOR
SGB Building Construction 
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY
-  
FIELD SUBFIELD
Field 12 - Physical Planning and Construction Building Construction 
ABET BAND UNIT STANDARD TYPE PRE-2009 NQF LEVEL NQF LEVEL CREDITS
Undefined  Regular  Level 2  NQF Level 02  10 
REGISTRATION STATUS REGISTRATION START DATE REGISTRATION END DATE SAQA DECISION NUMBER
Passed the End Date -
Status was "Reregistered" 
2018-07-01  2023-06-30  SAQA 06120/18 
LAST DATE FOR ENROLMENT LAST DATE FOR ACHIEVEMENT
2024-06-30   2027-06-30  

In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise.  

This unit standard does not replace any other unit standard and is not replaced by any other unit standard. 

PURPOSE OF THE UNIT STANDARD 
This is one of four Unit Standards for the installation of waterproofing systems. These systems play a critical role by ensuring that water does not penetrate through various surfaces and cause damage to them or that it does not create a health hazard through dampness. Learners will be able to assess a situation and know which waterproofing installation system they will need to use to perform the task.

Learners credited with this standard will be able to:
  • Demonstrate understanding of in-situ reinforced and non-reinforced liquid based waterproofing systems.
  • Prepare for waterproofing.
  • Install in-situ reinforced and non-reinforced liquid based waterproofing system. 

  • LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING 
  • Communication at NQF Level 1.
  • Mathematical Literacy at NQF Level 1. 

  • UNIT STANDARD RANGE 
    In-situ reinforced systems include: acrylic, bituminous emulsions, and cementitious. 

    Specific Outcomes and Assessment Criteria: 

    SPECIFIC OUTCOME 1 
    Demonstrate understanding of in-situ reinforced and non-reinforced liquid based waterproofing system. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    The in-situ reinforced and non-reinforced liquid based waterproofing systems is described in terms of its differences with the other waterproofing systems. 

    ASSESSMENT CRITERION 2 
    Health and safety requirements pertaining to the task are understood and adhered to ensure compliance with legislation, building regulations and safety. 

    ASSESSMENT CRITERION 3 
    Materials and equipment for in-situ reinforced and non-reinforced liquid based systems are transported, handled and stored according to standard operating procedure. 

    ASSESSMENT CRITERION 4 
    The drawings and scope of work are described to ensure that the work is performed within anticipated time frames according to system requirements. 

    ASSESSMENT CRITERION 5 
    Tools are inspected, used, cleaned and stored according to work procedure. 

    SPECIFIC OUTCOME 2 
    Prepare to install in-situ reinforced and non-reinforced liquid based waterproofing system on surfaces above ground (horizontal surfaces) and below ground (vertical surfaces). 
    OUTCOME RANGE 
    Preparation covers installation on vertical and horizontal surfaces and above or below ground. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    The condition of surface on which the waterproofing needs to be applied is evaluated and falls to outlets are established according to procedure related to horizontal surfaces-and possible drainage systems below ground (the bottom of vertical surfaces). 
    ASSESSMENT CRITERION RANGE 
    Conditions include suitability, soundness.
     

    ASSESSMENT CRITERION 2 
    Dangers and risks associated with open gas flame are identified and reported to relevant authority according to procedure where applicable with system being applied. 

    ASSESSMENT CRITERION 3 
    Surfaces are cleaned, swept and prepared according to procedure. 
    ASSESSMENT CRITERION RANGE 
    Preparation includes removal of sharp objects and protrusions, removal of dust, dirt and surface crud, and repair of surface defects where necessary.
     

    ASSESSMENT CRITERION 4 
    Priming of surface is performed where necessary to bind surface and lay dust, and is allowed to flash off (solvents to evaporate) according to procedure. 
    ASSESSMENT CRITERION RANGE 
    Priming includes binding surface, laying dust and flashing off.
     

    SPECIFIC OUTCOME 3 
    Install in-situ reinforced and non-reinforced liquid based waterproofing system above ground (Horizontal surfaces). 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    The membrane is evaluated and set out according to falls and prevailing weather as per procedure. 

    ASSESSMENT CRITERION 2 
    Installation is performed in accordance with manufacturer's specifications and detailing to suit the characteristics of the task. 

    ASSESSMENT CRITERION 3 
    Tests are conducted where possible and work handed over to supervisor according to procedure. 

    ASSESSMENT CRITERION 4 
    Site is cleared and made safe to client's satisfaction according to site-requirements. 

    SPECIFIC OUTCOME 4 
    Install in-situ reinforced and non-reinforced liquid based waterproofing system below ground (Vertical surfaces). 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    The membrane is evaluated and set out according to falls and prevailing weather as per procedure. 

    ASSESSMENT CRITERION 2 
    Installation is performed in accordance with manufacturer's specifications and detailing to suit the characteristics of the task. 

    ASSESSMENT CRITERION 3 
    Tests are conducted where possible and work handed over to supervisor. 

    ASSESSMENT CRITERION 4 
    Site is cleared and made safe to client's satisfaction. 


    UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS 
  • An assessor, accredited with a relevant NQF Level 4 or higher qualification, will assess the learner's competency. Only an Assessor with suitable first hand experience in process operations will assess the learner's competency.
  • Anyone assessing a learner or moderating the assessment of a learner against the qualification must be registered as an assessor with the relevant Education and Training Quality Assurance (ETQA) Body, or with an ETQA that has a Memorandum of Understanding with the relevant ETQA.
  • Any institution offering learning that will enable the achievement of this qualification must be accredited as a provider with the relevant Education and Training Quality Assurance (ETQA) Body, or with an ETQA that has a Memorandum of Understanding with the relevant ETQA.
  • Assessment and moderation of assessment will be overseen by the relevant Education and Training Quality Assurance (ETQA) Body, or by an ETQA that has a Memorandum of Understanding with the relevant ETQA, according to the ETQA's policies and guidelines for assessment and moderation.
  • Moderation must include both internal and external moderation of assessments, unless ETQA policies specify otherwise. Moderation should also encompass achievement of the competence described in the associated unit standards.
  • Anyone wishing to be assessed against this qualification may apply to be assessed by any assessment agency, assessor or provider institution that is accredited by the relevant ETQA. 

  • UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE 
    Waterproofing systems:
  • Health and safety and building regulations.
  • Waterproofing materials and equipment.
  • Dangers and risks associated with the work.
  • Tools.
  • Knowledge of drawings.
  • Manufacturer's specifications on use of systems, materials and equipment. 

  • UNIT STANDARD DEVELOPMENTAL OUTCOME 
    N/A 

    UNIT STANDARD LINKAGES 
    N/A 


    Critical Cross-field Outcomes (CCFO): 

    UNIT STANDARD CCFO IDENTIFYING 
    Identify and solve problems in which responses display that responsible decisions using critical and creative thinking have been made when:
  • Engaging with waterproofing problems. 

  • UNIT STANDARD CCFO WORKING 
    Work effectively with others as a member of a team, group, organisation, community to:
  • Ensure that the installation of waterproofing systems is completed according to standard procedure. 

  • UNIT STANDARD CCFO ORGANISING 
    Organise and manage oneself and one's activities responsively and effectively when:
  • Selecting and using the appropriate tools and materials for the task.
  • Installing waterproofing system.
  • Dealing with health and safety issues.
  • Meeting customer requirements. 

  • UNIT STANDARD CCFO COLLECTING 
    Collect, analyse, organise and critically evaluate information to:
  • Install waterproofing systems.
  • Solving waterproofing problems. 

  • UNIT STANDARD CCFO COMMUNICATING 
    Communicate effectively using visual, mathematical and/or language skills in the modes of oral and/or written presentation to:
  • Complete waterproofing installation.
  • Hand over job to supervisor or client. 

  • UNIT STANDARD CCFO SCIENCE 
    Use science and technology effectively and critically, showing responsibility towards the environment and the health of others by:
  • Using the equipment and materials according to manufacturer's instructions. 

  • UNIT STANDARD CCFO DEMONSTRATING 
    Demonstrate an understanding of the world as a set of related systems by recognising that the problem-solving contexts do not exist in isolation when engaging with waterproofing problems. 

    UNIT STANDARD ASSESSOR CRITERIA 
    N/A 

    REREGISTRATION HISTORY 
    As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. 

    UNIT STANDARD NOTES 
    N/A 

    QUALIFICATIONS UTILISING THIS UNIT STANDARD: 
      ID QUALIFICATION TITLE PRE-2009 NQF LEVEL NQF LEVEL STATUS END DATE PRIMARY OR DELEGATED QA FUNCTIONARY
    Core  65929   National Certificate: Waterproofing  Level 2  NQF Level 02  Passed the End Date -
    Status was "Reregistered" 
    2023-06-30  CETA 


    PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: 
    This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here.
     
    NONE 



    All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source.