All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Perform indoor wiring and cabling for CPE |
SAQA US ID | UNIT STANDARD TITLE | |||
10471 | Perform indoor wiring and cabling for CPE | |||
ORIGINATOR | ||||
SGB Telecommunications | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 06 - Manufacturing, Engineering and Technology | Manufacturing and Assembly | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 3 | NQF Level 03 | 12 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2018-07-01 | 2023-06-30 | SAQA 06120/18 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2024-06-30 | 2027-06-30 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard does not replace any other unit standard and is not replaced by any other unit standard. |
PURPOSE OF THE UNIT STANDARD |
This unit standard focuses on the field of Customer Premises Equipment (CPE).
A learner credited with this unit standard is capable of: This unit standard will contribute to the full development of any learner within the Telecommunications environment, more specifically within CPE by providing recognition, further mobility and transportability within the field. The knowledge, skills and understanding demonstrated in this unit standard are essential for upliftment, social and economic transformation in the Telecommunications environment. |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
The learning assumed to be in place should be on the same level of this unit standard or higher.
|
UNIT STANDARD RANGE |
The typical scope of this unit standard is limited to copper cable for:
The context of this unit standard is performed within structures where stationery, transportation, support structure, communication media, employer`s policies and procedures, cultural ethics, business ethics, work environment, professional conduct, test instrumentation, tools, human resources, role players, material, equipment, quality standards are applicable. The level assigned to this unit standard is appropriate because the learner: |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Plan to perform indoor wiring and cabling. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Job order is obtained according to employer's policies and procedures. |
ASSESSMENT CRITERION 2 |
2. Site is identified, inspected and role players are consulted according to job order and employer's policies and procedures. |
ASSESSMENT CRITERION 3 |
3. Task is scheduled according to customer requirements. |
ASSESSMENT CRITERION 4 |
4. Marked up and agreed upon site/floor plan is obtained, type of feed for cabling is determined and indoor distribution points are located in accordance with floor/site plan. |
ASSESSMENT CRITERION 5 |
5. Access points are identified according to site inspection and floor plan. |
ASSESSMENT CRITERION 6 |
6. Size of cables are identified and type of sockets are determined according to equipment specification and job order. |
ASSESSMENT CRITERION 7 |
7. Availability of Trunking and cable tray, tools, material, transportation and test equipment is identified according to job requirements. |
SPECIFIC OUTCOME 2 |
Prepare to perform indoor wiring and cabling. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Tools, material and test equipment is obtained and access points are opened according to job requirements. |
ASSESSMENT CRITERION 2 |
2. Cut-out points are identified according to floor/site plan. |
SPECIFIC OUTCOME 3 |
Perform indoor wiring and cabling. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Trunking and cable tray and draw wire is installed according to job requirements. |
ASSESSMENT CRITERION 2 |
2. Termination blocks are installed and cables are hauled according to job requirements and employer's policies and procedures. |
ASSESSMENT CRITERION 3 |
3. Cables are separated and cable ends are marked according to employer's policies and procedures. |
ASSESSMENT CRITERION 4 |
4. Cables are secured, quality test is conducted, identified and marking of the termination points is performed and cross connection is performed according to employer's policies and procedures. |
ASSESSMENT CRITERION 5 |
5. Indoor cabling to termination points is connected according to floor/site plan and employer's policies and procedures. |
ASSESSMENT CRITERION 6 |
6. Functionality of the installation is tested according to employer's policies and procedures and equipment specifications. |
SPECIFIC OUTCOME 4 |
Conclude indoor wiring and cabling. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Access points are restored. |
ASSESSMENT CRITERION 2 |
2. Documentation is completed accurately. |
ASSESSMENT CRITERION 3 |
3. Role players are consulted and work area is cleared of all waste material. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
Accreditation Options:
1. Anyone assessing a learner against this unit standard must be registered as an Assessor with the relevant ETQA. 2. Any institution offering learning that will enable achievement of this unit standard must be accredited as a provider through the relevant ETQA by SAQA. Moderation Option: Moderation of assessment will be overseen by the relevant ETQA according to the moderation guidelines and the agreed ETQA procedures. |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
Skills, Knowledge and Understanding:
|
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO IDENTIFYING |
Identify barriers pertaining to the indoor cabling & wiring and developed strategies to overcome them. |
UNIT STANDARD CCFO WORKING |
Work effectively with role players in order to ensure that indoor cabling is agreed upon and that customer`s requirements are met. |
UNIT STANDARD CCFO ORGANISING |
Manage activities in terms of preparation, planning, conducting and concluding indoor cabling & wiring effectively to ensure an accurate and professional service delivery. |
UNIT STANDARD CCFO COMMUNICATING |
Be culturally sensitive across a range of social contexts when consulting customers. |
UNIT STANDARD ASSESSOR CRITERIA |
Assessors should keep the following general principles in mind when designing and conducting assessments against this unit standard:
The portfolio may include: |
REREGISTRATION HISTORY |
As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. |
UNIT STANDARD NOTES |
Legal Requirements
Compliance to the following legal requirements and standards are mandatory: |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Core | 21798 | Certificate: Telecommunications for Customer Premises Equipment | Level 2 | NQF Level 02 | Passed the End Date - Status was "Reregistered" |
2009-10-03 | Was MICTS until Last Date for Achievement |
Core | 78963 | National Certificate: Telecommunications for Customer Premises Equipment | Level 2 | NQF Level 02 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | MICTS |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |