All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Inspect and clean medium / high voltage yards and enclosures |
SAQA US ID | UNIT STANDARD TITLE | |||
113887 | Inspect and clean medium / high voltage yards and enclosures | |||
ORIGINATOR | ||||
SGB Electrical Engineering & Construction | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 12 - Physical Planning and Construction | Electrical Infrastructure Construction | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 2 | NQF Level 02 | 2 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2007-04-03 | 2009-02-18 | SAQA 0160/05 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2010-02-18 | 2013-02-18 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard is replaced by: |
US ID | Unit Standard Title | Pre-2009 NQF Level | NQF Level | Credits | Replacement Status |
258941 | Inspect and clean Medium or High voltage yards and enclosures | Level 2 | NQF Level 02 | 2 |
PURPOSE OF THE UNIT STANDARD |
This unit standard is for persons working within the Distribution and Transmission environment to enable the inspections and cleaning of Medium / High Voltage yards.
A person credited with this unit standard will be able to: This unit standard will contribute to the full development of the learner within the electrical Distribution and Transmission environment. The skills, knowledge and understanding demonstrated within this unit standard are essential for social and economic transformation and upliftment within Geographical Information Sciences environment. |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
The following knowledge, skills attitude and / or equivalent:
|
UNIT STANDARD RANGE |
This unit standard applies to persons who will inspect and clean MV / HV yards and enclosures within the following range:
Inspections include, but are not limited to: Cleaning includes but is not limited to: Minor repairs (non-electrical) include, but are not limited to: |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Plan to inspect and clean a medium / high voltage yard / encloser |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Job instructions are interpreted correctly and access permits and documentation arranged according to statutory requirements. |
ASSESSMENT CRITERION 2 |
2. Appropriate tools, and equipment are identified and selected according to job requirements. |
ASSESSMENT CRITERION 3 |
3. Select the correct inspection sheets necessary to complete the task. |
ASSESSMENT CRITERION 4 |
4. Select the correct personal protective equipment and safety rules / regulations are interpreted and applied. |
SPECIFIC OUTCOME 2 |
Inspect Medium / High Voltage yards / enclosures and conduct minor repairs where necessary. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Ensure that necessary permits are received and workers` register completed. |
ASSESSMENT CRITERION 2 |
2. Complete risk analyses to ensure safe working environment. |
ASSESSMENT CRITERION 3 |
3. Inspection conducted and recorded according to prescribed inspection sheet. |
ASSESSMENT CRITERION 4 |
4. Minor repairs are carried out according to job specifications as per inspection sheet findings. |
SPECIFIC OUTCOME 3 |
Clean Medium / High Voltage yards / enclosures. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Cleaning of MV / HV yard is done according to the specified job requirements. |
ASSESSMENT CRITERION 2 |
2. Tools and cleaning material are used in accordance with environmental requirements. |
ASSESSMENT CRITERION 3 |
3. Safety-and-personal protective equipment is applied according to statutory requirements and safe work procedures. |
ASSESSMENT CRITERION 4 |
4. Cleaning of hazardous substance spills / leaks are done in accordance with statutory requirements. |
SPECIFIC OUTCOME 4 |
Conclude the task of inspecting and cleaning of medium / high voltage yards / enclosures. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Tools and cleaning materials are removed and stored according worksite procedure. |
ASSESSMENT CRITERION 2 |
2. All personnel are removed from the work site and access doors / gates are closed and locked according to the Operating Regulations for High Voltage Systems (ORHVS). |
ASSESSMENT CRITERION 3 |
3. Rubble, weeds and hazardous waste materials are disposed of as per environmental procedures. |
ASSESSMENT CRITERION 4 |
4. Inspection sheets are completed and submitted according to maintenance procedures. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
1. Anyone assessing a learner against this unit standard must be registered as an assessor with the relevant ETQA. |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
UNIT STANDARD DEVELOPMENTAL OUTCOME |
N/A |
UNIT STANDARD LINKAGES |
N/A |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO COLLECTING |
Collect, organise and critically evaluate information related to inspecting and cleaning Medium / High / Extra High Voltage yards / enclosures. |
UNIT STANDARD ASSESSOR CRITERIA |
N/A |
UNIT STANDARD NOTES |
This unit standard has been replaced by unit standard 258941, which is "Inspect and clean medium/high voltage yards and enclosures", Level 2, 2 credits.
Supplementary Information: Specified Requirements Specified requirements include legal and legislative specific requirements and are contained in one or more of the following documents: |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Elective | 48473 | National Certificate: Electrical Engineering | Level 2 | NQF Level 02 | Passed the End Date - Status was "Reregistered" |
2009-02-18 | Was EWSETA until Last Date for Achievement |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |