SAQA All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source.
SOUTH AFRICAN QUALIFICATIONS AUTHORITY 
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: 

Maintain process control loops 
SAQA US ID UNIT STANDARD TITLE
116042  Maintain process control loops 
ORIGINATOR
SGB Measurement, Control and Instrumentation 
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY
-  
FIELD SUBFIELD
Field 06 - Manufacturing, Engineering and Technology Engineering and Related Design 
ABET BAND UNIT STANDARD TYPE PRE-2009 NQF LEVEL NQF LEVEL CREDITS
Undefined  Regular  Level 4  NQF Level 04  10 
REGISTRATION STATUS REGISTRATION START DATE REGISTRATION END DATE SAQA DECISION NUMBER
Passed the End Date -
Status was "Reregistered" 
2007-09-18  2009-04-08  SAQA 0160/05 
LAST DATE FOR ENROLMENT LAST DATE FOR ACHIEVEMENT
2010-04-08   2013-04-08  

In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise.  

This unit standard is replaced by: 
US ID Unit Standard Title Pre-2009 NQF Level NQF Level Credits Replacement Status
262488  Perform routine maintenance on integrated process control loops  Level 4  NQF Level 04  15   

PURPOSE OF THE UNIT STANDARD 
This unit standard is for persons in the Manufacturing Engineering and Technology field.

A person credited with this unit standard will be able to:
  • Explain the principles and procedures (techniques) to be applied during maintenance of Process Control Loops.
  • Plan and prepare for maintaining Process Control Loops.
  • Find faults on Process Control Loops.
  • Repair Process Control Loops.

    This unit standard will contribute to the development of the learner within the Measurement Control and Instrumentation environment by providing recognition, further mobility and transportability within the field of Manufacturing Engineering and Technology. The skills, knowledge and understanding demonstrated within this unit standard are essential for social and economic transformation and development within the Measurement Control and Instrumentation environment. 

  • LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING 
    The following knowledge, skills attitude and / or equivalent:
  • Safety procedures according to statutory and manufacturer requirements.
  • Knowledge of equipment according to range statement.
  • Interpret Instrumentation and Process drawings and sketches.
  • Fault finding techniques on Field Instrumentation.
  • Induction to industry.
  • Basic electrical safety.
  • Use and care of relevant testing, measuring equipment and hand tools. 

  • UNIT STANDARD RANGE 
    Process control loops includes but is not limited to pressure, level, temperature, flow, density, mass, and vibration.

    The range of process control loops includes but is not limited to, open loops, closed loops, cascade loops and ratio control loops.

    Maintaining process control loops includes isolation, removal, calibration, installation and commissioning.

    Safety precautions include the use of all personal protective equipment, electrical and fire protection.
    Requirements include but are not limited to Statutory requirements, National Standards and manufacturers specifications. 

    Specific Outcomes and Assessment Criteria: 

    SPECIFIC OUTCOME 1 
    Establish conditions for maintaining Process Control Loops. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Work area is prepared as per procedure. 

    ASSESSMENT CRITERION 2 
    Tools are selected as per task requirement. 

    ASSESSMENT CRITERION 3 
    Appropriate manuals are selected. 

    ASSESSMENT CRITERION 4 
    Safety equipment is obtained where necessary. 

    ASSESSMENT CRITERION 5 
    Documentation is obtained as per procedure. 

    SPECIFIC OUTCOME 2 
    Diagnose faults in Process Control Loops. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Appropriate test equipment is selected. 

    ASSESSMENT CRITERION 2 
    Test equipment is connected and set up according to manufacturer's instructions. 

    ASSESSMENT CRITERION 3 
    Test is performed and values are compared against values on application data sheets. 

    ASSESSMENT CRITERION 4 
    Decommission Process Control Loops in accordance with procedures. 

    SPECIFIC OUTCOME 3 
    Repair equipment in a Process Control Loop. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Functional tests are performed according to manufacturer's instructions. 

    ASSESSMENT CRITERION 2 
    Faulty components are identified and repaired or replaced. 

    ASSESSMENT CRITERION 3 
    Equipment and the process control loop is re-assembled and calibrated according to manufacturer's instructions. 

    SPECIFIC OUTCOME 4 
    Establish normal operating conditions after completion. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Commission Process Control Loops in accordance with procedures. 

    ASSESSMENT CRITERION 2 
    Work area is restored and tidied, and equipment is stored according to procedure. 

    ASSESSMENT CRITERION 3 
    Documentation is completed. 

    ASSESSMENT CRITERION 4 
    Test equipment is disconnected and stored according to procedure. 


    UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS 
  • Anyone assessing a learner against this unit standard must be registered as an assessor with the relevant ETQA.
  • Any institution offering learning that will enable achievement of this unit standard must be accredited as a provider through the relevant ETQA by SAQA.
  • Moderation of assessment will be overseen by the relevant ETQA according to the moderation guidelines in the relevant qualification and the agreed ETQA procedures. 

  • UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE 
  • Workshop procedures including house keeping practices according to statutory requirements.
  • Specific work site safety practices relating to the Process Control Loops including the use of personal protective equipment, electrical and fire protection.
  • A basic understanding of:
    (a) The effects of fault finding, repairing and maintaining on production.
    (b) Applicable manufactures specifications.
    (c) Documentation required for activity.
    (d) Characteristics and procedures of equipment.
  • A comprehensive understanding of:
    (a) Applicable work site procedures.
    (b) Reporting systems.
    (c) Identification, location and function of appropriate tools, measuring instruments, materials, personal protective equipment.
    (d) Names and functions of equipment.
    (e) Fault finding, repair and maintenance principles and procedures (techniques).
    (f) Interpret and draw schematic diagrams.
    (g) Potential faults on equipment.
    (h) Characteristics and properties of system operations.
    (i) Working principles associated with fault finding and repairing Process Control Loops are theoretically and practically explained.
  • Names, locations and functions of Process Control Loops and their accessories.
  • Hazards and preventive precautions associated with Process Control Loops.
  • Company standards. 

  • UNIT STANDARD DEVELOPMENTAL OUTCOME 
    N/A 

    UNIT STANDARD LINKAGES 
    N/A 


    Critical Cross-field Outcomes (CCFO): 

    UNIT STANDARD CCFO IDENTIFYING 
    Identification and problem solving skills - faulty equipment and process control loops identified and reported. 

    UNIT STANDARD CCFO WORKING 
    Work effectively with others - working under supervision. 

    UNIT STANDARD CCFO COMMUNICATING 
    Communication skills - reporting faulty Process Control Loops and associated equipment and interpreting job requirements. 

    UNIT STANDARD ASSESSOR CRITERIA 
    N/A 

    UNIT STANDARD NOTES 
    This unit standard has been replaced by unit standard 262488, which is "Perform routine maintenance on integrated process control loops", Level 4, 15 credits. 

    QUALIFICATIONS UTILISING THIS UNIT STANDARD: 
      ID QUALIFICATION TITLE PRE-2009 NQF LEVEL NQF LEVEL STATUS END DATE PRIMARY OR DELEGATED QA FUNCTIONARY
    Core  48919   Further Education and Training Certificate: Measurement, Control and Instrumentation  Level 4  NQF Level 04  Passed the End Date -
    Status was "Reregistered" 
    2009-04-08  Was EWSETA until Last Date for Achievement 


    PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: 
    This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here.
     
    NONE 



    All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source.