SAQA All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source.
SOUTH AFRICAN QUALIFICATIONS AUTHORITY 
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: 

Wire components of an axle counter 
SAQA US ID UNIT STANDARD TITLE
116893  Wire components of an axle counter 
ORIGINATOR
SGB Electrical Engineering & Construction 
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY
-  
FIELD SUBFIELD
Field 12 - Physical Planning and Construction Electrical Infrastructure Construction 
ABET BAND UNIT STANDARD TYPE PRE-2009 NQF LEVEL NQF LEVEL CREDITS
Undefined  Regular  Level 3  NQF Level 03 
REGISTRATION STATUS REGISTRATION START DATE REGISTRATION END DATE SAQA DECISION NUMBER
Passed the End Date -
Status was "Reregistered" 
2018-07-01  2023-06-30  SAQA 06120/18 
LAST DATE FOR ENROLMENT LAST DATE FOR ACHIEVEMENT
2024-06-30   2027-06-30  

In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise.  

This unit standard does not replace any other unit standard and is not replaced by any other unit standard. 

PURPOSE OF THE UNIT STANDARD 
A learner credited with this unit standard will be able to wire components of an axle counter according to plans and specifications by applying signalling engineering practice. This will ensure the availability of correctly wired components of an axle counter, which contribute in part to a reliable railway signalling system, safe and efficient train operations and effective rail transportation. 

LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING 
  • Communication NQF L2
  • Mathematics NQF L2
  • Knowledge of the principles of electricity.
  • Knowledge of and ability to use engineering hand and power tools.
  • Knowledge of and ability to route and terminate electrical conductors. 

  • UNIT STANDARD RANGE 
    The credit value assigned to this unit standard is appropriate because performance must be carried out:
    1. In a controlled environment.
    2. Within a specific time.
    3. At a field site or in a workshop.

    This standard includes:
  • The wiring of axle counter racks
  • The wiring of axle counter trackside equipment

    This standard excludes the wiring of the electronic components of an Axle counter 

  • Specific Outcomes and Assessment Criteria: 

    SPECIFIC OUTCOME 1 
    Plan and procure the resources required to perform the wiring of components of an axle counter safely and according to plan and specifications 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    The job order is interpreted to establish the relevant resources required to perform the wiring task as per wiring diagram and signalling specifications 

    ASSESSMENT CRITERION 2 
    The correct plans for the wiring of components of an axle counter are obtained and verified. 

    ASSESSMENT CRITERION 3 
    The correct resource requirements are determined and obtained to perform the wiring task on an axle counter. 

    ASSESSMENT CRITERION 4 
    The resources are verified against material specifications and any sub-standards rectified. 

    SPECIFIC OUTCOME 2 
    Wire components of an axle counter safely and correctly according to a wiring diagram/schedule and specifications, within the allocated time at a suitable site. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    A component of an axle counter is wired as per plan/schedule and specification 

    ASSESSMENT CRITERION 2 
    Safe working procedures, policies and instructions are adhered to. 

    ASSESSMENT CRITERION 3 
    The assisting personnel are supervised when applicable. 

    ASSESSMENT CRITERION 4 
    A suitable and safe site is prepared and secured according to procedures, policies and instructions. 

    ASSESSMENT CRITERION 5 
    Wiring of components of an axle counter is completed within the allocated time. 

    ASSESSMENT CRITERION 6 
    Unforeseen circumstances related to the wiring of components of an axle counter are correctly dealt with. 

    SPECIFIC OUTCOME 3 
    Perform quality checks on wired components of an axle counter according to procedures, policies and instructions 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Relevant quality checks are performed correctly on wired components of an axle counter according to procedures, policies and instructions. 

    ASSESSMENT CRITERION 2 
    Quality checks indicating non-conformance to specifications are addressed correctly. 

    ASSESSMENT CRITERION 3 
    Relevant documentation related to the quality checks performed on wired components of an axle counter is completed according to procedures, policies and instructions. 

    ASSESSMENT CRITERION 4 
    Communication related to the wiring of components of an axle counter is carried out effectively. 

    ASSESSMENT CRITERION 5 
    Applicable documentation is completed according to company policies and instructions. 

    SPECIFIC OUTCOME 4 
    Restore the site and store or secure the wired components of an axle counter as per company-specific procedures, policies and instructions 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Hazardous and waste materials are safely disposed of as per company-specific procedures, policies and instructions. 

    ASSESSMENT CRITERION 2 
    All equipment housing lids, doors, covers, locks etc. are replaced and secured as per company-specific procedures policies and instructions. 

    ASSESSMENT CRITERION 3 
    The site is restored as per company-specific procedures, policies and instructions. 

    ASSESSMENT CRITERION 4 
    The wired component of an axle counter are stored or secured as per company specific procedures, policies and instructions. 

    ASSESSMENT CRITERION 5 
    Material, equipment and tools are returned for storage or repair as per company-specific procedures, policies and instructions. 


    UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS 
  • An individual wishing to be assessed against this unit standard may apply to an assessment agency, assessor or provider institution that has been accredited by the relevant ETQA.
  • Anyone assessing a learner against this unit standard must be registered as an assessor with the relevant ETQA.
  • Any institution offering learning that will enable achievement of this unit standard must be registered and accredited as a provider with the relevant ETQA as prescribed.
  • Moderation of assessment will be done by the relevant ETQA as prescribed.
  • Anyone assessing a learner against this unit standard must be certified as competent against this unit standard and registered as an assessor to assess this unit standard. 

  • UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE 
    The learners can understand and explain the following related to the wiring of an axle counter:
  • Planning and procurement
  • Wiring plans/diagrams/schedules/symbols
  • Identification, purpose and function of the parts and components of an Axle counter
  • Various types and functions of an axle counter
  • Wiring methods
  • Wiring/termination practices and company-specific specifications
  • Soft soldering tools, equipment and methods
  • Use of applicable soldering and wire termination tools
  • Identification and handling of materials
  • Function, purpose and safe use of applicable electrical test instruments
  • Restoration of site
  • Relevant extracts from
    OHS Act and regulations
    Safe working procedures
    Company-specific policies, procedures and instructions 

  • UNIT STANDARD DEVELOPMENTAL OUTCOME 
    N/A 

    UNIT STANDARD LINKAGES 
    N/A 


    Critical Cross-field Outcomes (CCFO): 

    UNIT STANDARD CCFO IDENTIFYING 
    Problem-solving
    Learners can solve problems with regard to:
  • The correctness, quantity and quality of material, parts and components
  • The suitability and functionality of equipment and tools
  • The wiring of electrical equipment
  • Operational changes relating to the wiring of electrical circuits
  • Availability and competence of assisting personnel 

  • UNIT STANDARD CCFO WORKING 
    Team work
    Learners can work effectively in teams when:
  • Handling and wiring of electrical equipment
  • Storing or securing of electrical equipment
  • Restoring the site 

  • UNIT STANDARD CCFO ORGANISING 
    Self-organisation and self-management
    A learner can organise and manage himself by:
  • Executing the task responsibly
  • Maintaining a high level of discipline
  • Adherence to time frames
  • Adherence to safety and company-specific policies and procedures 

  • UNIT STANDARD CCFO COLLECTING 
    Information evaluation
    Learners can interpret and evaluate the contents of:
  • A wiring plan/diagram
  • A job order 

  • UNIT STANDARD CCFO COMMUNICATING 
    Communication
  • Learners can communicate effectively with relevant role-players related to the wiring of electrical equipment. 

  • UNIT STANDARD CCFO SCIENCE 
    Use of science and technology
    Learners can use science and technology by using:
  • Electrical tools and test instruments 

  • UNIT STANDARD CCFO DEMONSTRATING 
    Inter-relatedness of systems
  • Learners can understand the role of the axle counter in a railway signalling system. 

  • UNIT STANDARD CCFO CONTRIBUTING 
    Learner and societal development
    Learners can understand the importance of:
  • Safety in the workplace as well as in the whole environment
  • Being a team player in the work environment and in society
  • Communicating effectively in the work environment and in society
  • Their responsibility for the safety and well-being of fellow-workers and society at large 

  • UNIT STANDARD ASSESSOR CRITERIA 
    N/A 

    REREGISTRATION HISTORY 
    As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. 

    UNIT STANDARD NOTES 
    Until 7 April 2005, this unit standard was incorrectly recorded as "Wire components of a remote control system". SAQA apologises for the inconvenience caused by this.

    Assessment process:

    Assessment methods:
  • Written tests.
  • Practical test.
  • Oral questioning.
  • Observation of practical task execution.
  • Simulation.
  • Role-play/structured classroom discussions and oral tests.
  • Practical verification against specifications

    These methods must be selected carefully based on the purpose of the assessment (for example, the written method could be used to assess knowledge or on-the-job demonstration for practical competence). The assessment must integrate a number of different methods (no less than three of those detailed above) in order to give the assessor reliable and valid proof of competence and evidence of required attitudes.


    The following may be used to supplement the above minimum assessment methods:

    Valid, reliable and authentic evidence (presented as a portfolio of evidence) from past achievements and experience may serve to supplement the assessment of applied competence. The portfolio should include inter alia:
  • Written statements from persons (e.g. current and/or previous employer, colleague, peer, manager, external customers) confirming competence of the learner.
  • Relevant certificates or awards.
  • Previous assessment records.
  • Logbook or register stating evidence of performance

    Values:
    In addition, the following values should be demonstrated:
  • Safety consciousness
  • Responsibility
  • Integrity
  • Quality consciousness
  • Time consciousness
  • Sobriety

    Supplementary information:

    Terminology

    Job order refers to:
  • Job card
  • Job instruction
    Plan refers to a drawing or diagram
    Sub-standard refers to the deviation from specifications and/or standards
    Site refers to a workshop or field location
    Communication can include, but is not limited to:
  • Personnel structures, e.g. supervisors and subordinates
  • Verification of messages/instructions
    Communication media can include, but is not limited to:
  • 2-way radios
  • Cellular phones
  • Trunk radios
  • Hand-held emergency telephones.
    Secure means to make safe, cover, fasten or tie down.
    Logbook refers to evidence of training and job performance.
    Store/storage means to remove item(s) from the work area and place in a designated/prescribed area as per company-specific procedures, policies and instructions.
    Wiring means connecting individual electrical parts/components to each other by means of electrical/optical conductors.
    Trackside box refers to the housing into which the rail interface equipment is mounted.
    Standard railway axle counter rack refers to a pre-assembled rack with backboards to which standard modules are fitted.
    Components refer to the modular parts.


    Certification
    The learner will be certified as competent when a standard axle counter rack and associated track side equipment have been correctly wired to specification.

    Credits
    Total hours required by the learner to achieve the required outcomes:

    Activity - Hours
    Theory-12
    Practical-18
    Self-directed learning-2
    On-the-job learning-6
    Assessment-6
    Total-44
    Credits achieved: 4 

  • QUALIFICATIONS UTILISING THIS UNIT STANDARD: 
      ID QUALIFICATION TITLE PRE-2009 NQF LEVEL NQF LEVEL STATUS END DATE PRIMARY OR DELEGATED QA FUNCTIONARY
    Elective  49068   National Certificate: Railway Signalling: Assembly and Wiring of Equipment  Level 2  NQF Level 02  Passed the End Date -
    Status was "Reregistered" 
    2023-06-30  TETA 


    PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: 
    This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here.
     
    NONE 



    All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source.