All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Originate keys |
SAQA US ID | UNIT STANDARD TITLE | |||
123587 | Originate keys | |||
ORIGINATOR | ||||
SGB Security | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 08 - Law, Military Science and Security | Safety in Society | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 3 | NQF Level 03 | 11 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2018-07-01 | 2023-06-30 | SAQA 06120/18 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2024-06-30 | 2027-06-30 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard does not replace any other unit standard and is not replaced by any other unit standard. |
PURPOSE OF THE UNIT STANDARD |
Learners credited with this unit standard are able to identify a key blank for a locking mechanism, prepare the locking mechanism for key origination and cut the key to fit the locking mechanism. They will also be able to re-assemble the lock to it full functionality and integrity.
The qualifying learner is able to: |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
UNIT STANDARD RANGE |
The term "originate" refers to but is not limited to creating a key without an original using manual and or mechanical mechanisms. |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Identify the locking mechanism and key blank. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Type of lock is identified in terms of its operating principles. |
ASSESSMENT CRITERION 2 |
Identified key blank is matched to the lock. |
ASSESSMENT CRITERION 3 |
Identified key blank is prepared to match the lock. |
ASSESSMENT CRITERION RANGE |
Preparation includes but is not limited to modifications of the key blank. |
SPECIFIC OUTCOME 2 |
Strip locking mechanism for key origination. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Locking mechanisms are identified according to their mechanics and operations. |
ASSESSMENT CRITERION 2 |
Tools needed for stripping the locking mechanisms are selected for use. |
ASSESSMENT CRITERION 3 |
The locking mechanism is stripped according to standard operating procedures. |
ASSESSMENT CRITERION 4 |
Key blanks are matched against the locking mechanism in order to facilitate key origination. |
SPECIFIC OUTCOME 3 |
Cut an original key. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Locksmithing tools are selected in accordance with the job requirements. |
ASSESSMENT CRITERION RANGE |
Key cutting tools could include but are not limited to files, screw drivers, hand picks, pick gun, punches, chisels, hammers, drills and bits, scribe, gauges, venire/callipers, squares, hacksaws, pliers. |
ASSESSMENT CRITERION 2 |
The process to cut an original key is described in accordance with job specifications. |
ASSESSMENT CRITERION 3 |
Progressive verification of the origination process is demonstrated in accordance with organisational standards and procedures. |
ASSESSMENT CRITERION 4 |
An original key is cut in accordance with job specifications. |
SPECIFIC OUTCOME 4 |
Re-assemble the lock. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Component parts are verified in line with job requirements. |
ASSESSMENT CRITERION RANGE |
Component parts include but are not limited to bolts, levers, wafer, spring, pins. |
ASSESSMENT CRITERION 2 |
Functionality is restored in accordance with job specifications. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
UNIT STANDARD DEVELOPMENTAL OUTCOME |
N/A |
UNIT STANDARD LINKAGES |
N/A |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO IDENTIFYING |
Identify and solve problems relating to the selection of correct tools and preparation of the work area for the purpose of correctly originating keys. |
UNIT STANDARD CCFO WORKING |
Work effectively with others when preparing for and cutting a key. |
UNIT STANDARD CCFO ORGANISING |
Organise oneself and one's activities so that all requirements are met in originating relevant keys. |
UNIT STANDARD CCFO COLLECTING |
Collect, evaluate, organise and critically evaluate information related to the identification of correct locking mechanisms and key blanks so that these are accurately interpreted into application. |
UNIT STANDARD CCFO COMMUNICATING |
Communicate effectively when dealing with customers. |
UNIT STANDARD CCFO DEMONSTRATING |
Demonstrate an understanding of the world as a set of related systems where the incorrect key blank will result in unnecessary expenditure and possible damage to the locking mechanism. |
UNIT STANDARD CCFO CONTRIBUTING |
In order to contribute to the full personal development of each learner and the social and economic development of society at large, it must be the intention underlying any programme of learning to make an individual aware of the importance of reflecting on and exploring a variety of strategies to learn more effectively. |
UNIT STANDARD ASSESSOR CRITERIA |
N/A |
REREGISTRATION HISTORY |
As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. |
UNIT STANDARD NOTES |
N/A |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Core | 50541 | National Certificate: Locksmithing | Level 3 | NQF Level 03 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | SAS SETA |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |