All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Demonstrate knowledge of regulatory requirements for permit to work systems |
SAQA US ID | UNIT STANDARD TITLE | |||
13600 | Demonstrate knowledge of regulatory requirements for permit to work systems | |||
ORIGINATOR | ||||
SGB Power Plant Operations | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 06 - Manufacturing, Engineering and Technology | Manufacturing and Assembly | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 5 | Level TBA: Pre-2009 was L5 | 10 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2018-07-01 | 2023-06-30 | SAQA 06120/18 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2024-06-30 | 2027-06-30 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard does not replace any other unit standard and is not replaced by any other unit standard. |
PURPOSE OF THE UNIT STANDARD |
People credited with this unit standard are able to describe the requirements to apply a permit to work; describe the requirements for a lockout system; describe the requirements for testing of plant and or apparatus. |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
1. Listen, question, observe, describe and accurately align with the sender`s need.
2. Understand and respect peoples values and beliefs as well as those of the organisation and manage his/her actions in line with the above. 3. Understands one`s own development requirements. 4. Understands the company`s vision and manage their actions in line with it. 5. Specific organisation safety standards. 6. Basic first aid. 7. Fire fighting. 8. Specific emergency preparedness. 9. Problem solving and decision making. 10. Environmental awareness. 11. Organisation understanding. |
UNIT STANDARD RANGE |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Describe the requirements to apply a permit. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Authorisation requirements are described according to organisational requirements. |
ASSESSMENT CRITERION RANGE |
Issuer and receiver of permit |
ASSESSMENT CRITERION 2 |
2. The description outlines the method used for the requisition of plant and or electrical apparatus for maintenance according to organisational requirements. |
ASSESSMENT CRITERION 3 |
3. The method used for preparing for maintenance plant and or electrical apparatus is described according to organisational safety standards. |
ASSESSMENT CRITERION RANGE |
Includes responsibilities of authorised person. |
ASSESSMENT CRITERION 4 |
4. The method used for cancelation of authorisation for maintenance on plant and or electrical apparatus is described according to organisational standards. |
ASSESSMENT CRITERION 5 |
5. The method used for the return of plant and or electrical apparatus to service is described according to organizational standards. |
SPECIFIC OUTCOME 2 |
Desribe the requirements for a lock-out system. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. The description outline the system used to ensure security of all points of isolation according to organisational
standards. |
ASSESSMENT CRITERION 2 |
2. The description outline the means which is used to ensure security of all points of isolation according to
organisational requirements. |
ASSESSMENT CRITERION 3 |
3. The description outlines the method of access control to restricted areas according to organisational requirements. |
ASSESSMENT CRITERION RANGE |
Electrical, mechanical and hazardous substance areas |
SPECIFIC OUTCOME 3 |
Describe the requirements of testing plant and electrical apparatus during authorised maintenance. |
OUTCOME NOTES |
Describe the requirements of testing plant and or electrical apparatus during authorised maintenance. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. The regulatory requirements for testing of plant and or electrical apparatus before returning to service are described according to organisational standards. |
ASSESSMENT CRITERION RANGE |
Mechanical, electrical and hazardous substances |
ASSESSMENT CRITERION 2 |
2. The responsibilities of the issuer of the test permit are described according to organisational standards. |
ASSESSMENT CRITERION 3 |
3. The responsibilities of the receiver of the test permit are described according to organisational standards. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
Accreditation : Evaluation of documentation and registration thereof according to SAQA approved process.
Moderation : Power Plant Operations SGB. |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
1. Relevant documentation procedure knowledge.
2. Understand the trends and or incidents related to the specific regulatory requirement application. 3. Regulatory procedure knowledge. |
UNIT STANDARD DEVELOPMENTAL OUTCOME |
N/A |
UNIT STANDARD LINKAGES |
N/A |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO IDENTIFYING |
Identifying & solving problems in which responses display that responsible decisions using critical and creative thinking have been made. |
UNIT STANDARD CCFO WORKING |
Working effectively with others as a member of a team, group, organization, and community. |
UNIT STANDARD CCFO ORGANISING |
Organising and managing oneself and one`s activities responsibly and effectively. |
UNIT STANDARD CCFO COLLECTING |
Collecting, analysing, organizing and critically evaluating information. |
UNIT STANDARD CCFO COMMUNICATING |
Communicating effectively using visual, mathematical and/or language skills in the modes of oral and/or written persuasion. |
UNIT STANDARD CCFO SCIENCE |
Using science and technology effectively and critically, showing responsibility towards the environment and health of others. |
UNIT STANDARD CCFO DEMONSTRATING |
Demonstrating an understanding of the world as a set of related systems by recognizing that problem-solving contexts do not exist in isolation. |
UNIT STANDARD CCFO CONTRIBUTING |
Contributing to the full personal development of each learner and the social and economic development of the society at large, by making it the underlying intention of any programme of learning to make an individual aware of the importance of:
a. Reflecting on and exploring a variety of strategies to learn more effectively; b. Participating as responsible citizens in the life of local, national and global communities; c. Being culturally and aesthetically sensitive across a range of social contexts; d. Exploring education and career opportunities; e. Developing entrepreneurial opportunities. |
UNIT STANDARD ASSESSOR CRITERIA |
N/A |
REREGISTRATION HISTORY |
As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. |
UNIT STANDARD NOTES |
Terminology used in this unit standard is consistent with the following:
A candidate will be regarded not yet competent should the safety of people, plant and materials be jeopardised during any stage of the assessment. |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Core | 48978 | Further Education and Training Certificate: Electrical Network Control | Level 4 | NQF Level 04 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | EWSETA |
Core | 61569 | Further Education and Training Certificate: Power Plant Operations | Level 4 | NQF Level 04 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | EWSETA |
Core | 23679 | National Diploma: Fossil Power Plant Process Control | Level 5 | Level TBA: Pre-2009 was L5 | Passed the End Date - Status was "Reregistered" |
2009-02-18 | Was EWSETA until Last Date for Achievement |
Core | 23736 | National Diploma: Hydro Power Plant Process Control | Level 5 | Level TBA: Pre-2009 was L5 | Passed the End Date - Status was "Reregistered" |
2009-02-18 | Was EWSETA until Last Date for Achievement |
Core | 23734 | National Diploma: Nuclear Power Plant Process Control | Level 5 | Level TBA: Pre-2009 was L5 | Passed the End Date - Status was "Reregistered" |
2009-02-18 | Was EWSETA until Last Date for Achievement |
Fundamental | 61570 | National Diploma: Power Plant Process Control Operations | Level 5 | NQF Level 05 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | EWSETA |
Elective | 23678 | National Certificate: Fossil Power Plant Operation | Level 4 | Level TBA: Pre-2009 was L4 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | EWSETA |
Elective | 23735 | National Certificate: Hydro Power Plant Operation | Level 4 | Level TBA: Pre-2009 was L4 | Passed the End Date - Status was "Reregistered" |
2009-02-18 | Was EWSETA until Last Date for Achievement |
Elective | 23733 | National Certificate: Nuclear Power Plant Operation | Level 4 | Level TBA: Pre-2009 was L4 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | EWSETA |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
1. | Kelvin Power (Pty) Ltd |
2. | MPUMELELO TRAINING |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |