All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Install Closed Circuit Television (CCTV) |
SAQA US ID | UNIT STANDARD TITLE | |||
244320 | Install Closed Circuit Television (CCTV) | |||
ORIGINATOR | ||||
SGB Security | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 08 - Law, Military Science and Security | Safety in Society | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 4 | NQF Level 04 | 9 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2018-07-01 | 2023-06-30 | SAQA 06120/18 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2024-06-30 | 2027-06-30 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard does not replace any other unit standard and is not replaced by any other unit standard. |
PURPOSE OF THE UNIT STANDARD |
This unit standard is for persons who install CCTV systems in various sectors. Learners will not just be able to install these systems and will also be able to verify the use of components in a specific application. Installing includes the mounting and configuration of the CCTV systems. Learners will also be able to use CCTV testing equipment to ensure proper installation.
A person credited with this unit standard will be able to: |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
> ID 244328: Apply cabling methods, NQF Level 3. > ID 244321: Use elementary electronics as applied to electronic systems, NQF Level 3. > ID 244333: Install electronic equipment, NQF Level 4. > ID 244323: Determine installation requirements, NQF Level 4. > ID 244326: Explain the use of installed systems. > ID 244337: Demonstrate an understanding of CCTV, NQF Level 4. |
UNIT STANDARD RANGE |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Verify components suitability for the application. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Functionality of equipment is confirmed before installation. |
ASSESSMENT CRITERION 2 |
CCTV equipment configuration features are assessed to confirm that the equipment meets the operational requirements. |
ASSESSMENT CRITERION RANGE |
Configuration features may include but are not limited to, back focus, lens focus, iris adjustment, lens type, lens format, camera type, camera format, backlight compensation, Automatic Gain Control (AGC), shutter speed, contrast, brightness, component termination, video motion detection (VMD), frame rate, image quality, dwell time, time lapse speed. |
ASSESSMENT CRITERION 3 |
CCTV cable requirements are identified and described in terms of their advantages, disadvantages and limitations. |
ASSESSMENT CRITERION RANGE |
CCTV Cable requirements must include but are not limited to, video signal, control data, coaxial (RG-179, RG-59, RG-59U, RG-11, RG-11U-cable categories), twisted pair, cable screening. |
SPECIFIC OUTCOME 2 |
Mount and install CCTV components. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Equipment positions are determined to optimise functionality in line with operational requirements. |
ASSESSMENT CRITERION 2 |
Cable selection and routing are described in line with installation operational requirements. |
ASSESSMENT CRITERION 3 |
CCTV equipment is installed to meet operational requirements of the installation. |
ASSESSMENT CRITERION 4 |
CCTV equipment is configured in line with operational requirements. |
ASSESSMENT CRITERION RANGE |
Configuration may include but are not limited to back focus, lens focus, Iris adjustment, lens type, lens format, camera type, camera format, backlight compensation, Automatic Gain Control (AGC), shutter speed, contrast, brightness, component termination, video motion detection (VMD), frame rate, image quality, dwell time, time lapse speed. |
SPECIFIC OUTCOME 3 |
Use CCTV test equipment. |
OUTCOME RANGE |
CCTV Test equipment may include but is not limited to, neutral density (ND) filters, multi-meters, bar generators, cable length meter, oscilloscope, lux meter, view finder, video level meter, test monitors. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Test equipment is checked for external damage and correct calibration date. |
ASSESSMENT CRITERION 2 |
Test equipment is explained in terms of use and functionality. |
ASSESSMENT CRITERION 3 |
Test equipment is applied in terms of use and functionality. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
UNIT STANDARD DEVELOPMENTAL OUTCOME |
N/A |
UNIT STANDARD LINKAGES |
N/A |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO IDENTIFYING |
Identify and solve problems when installing CCTV systems/equipment, ensuring possible obstacles can be anticipated and alternative solutions/options implemented. |
UNIT STANDARD CCFO WORKING |
Work effectively as member of a team when conducting the installation. |
UNIT STANDARD CCFO ORGANISING |
Organise and manage one and ones activities when conducting installations, ensuring all possible scenarios` are taken into account and the work can happen on time. |
UNIT STANDARD CCFO COLLECTING |
Collect, analyse, organise and critically evaluate information when interpreting work orders, manufacturers` specifications and building plans, ensuring accurate information is used in the installation process. |
UNIT STANDARD CCFO COMMUNICATING |
Communicate effectively with client ensuring all parties are sure of exactly what is required. |
UNIT STANDARD CCFO SCIENCE |
Use science and technology effectively when installing CCTV systems/equipment, ensuring these will function optimally. |
UNIT STANDARD CCFO DEMONSTRATING |
Demonstrate an understanding of the relationship between accurate, comprehensive installation, client satisfaction, quality and repeat business. |
UNIT STANDARD ASSESSOR CRITERIA |
N/A |
REREGISTRATION HISTORY |
As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. |
UNIT STANDARD NOTES |
N/A |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Elective | 58697 | Further Education and Training Certificate: Electronic Security Installation Practices | Level 4 | NQF Level 04 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | As per Learning Programmes recorded against this Qual |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
1. | ADT SECURITY SERVICES PTY LTD |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |