All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Handle and care for portable electrical earthing gear and related equipment |
SAQA US ID | UNIT STANDARD TITLE | |||
258938 | Handle and care for portable electrical earthing gear and related equipment | |||
ORIGINATOR | ||||
SGB Electrical Engineering & Construction | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 12 - Physical Planning and Construction | Electrical Infrastructure Construction | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 2 | NQF Level 02 | 2 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2018-07-01 | 2023-06-30 | SAQA 06120/18 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2024-06-30 | 2027-06-30 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard replaces: |
US ID | Unit Standard Title | Pre-2009 NQF Level | NQF Level | Credits | Replacement Status |
113868 | Handle and care of electrical earthing gear and related equipment | Level 2 | NQF Level 02 | 2 |
PURPOSE OF THE UNIT STANDARD |
This unit standard is for persons who maintain portable earthing gear and related equipment.
A person credited with this unit standard will be able to: This unit standard will contribute to the full development of the learner within the electrical distribution environment. The skills, knowledge and understanding demonstrated within this unit standard are essential for social and economic transformation and upliftment within Geographical Information Sciences environment. |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
The following knowledge, skills attitude and/or equivalent:
|
UNIT STANDARD RANGE |
This unit standard applies to persons handling, inspecting, cleaning and storing portable electrical earthing gear and related equipment independently.
Earthing gear may include, but is not limited to: Related equipment include: |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Demonstrate knowledge of portable electrical earthing gear. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The importance of ensuring proper application of portable electrical earthing gear on isolated circuits is explained. |
ASSESSMENT CRITERION 2 |
An understanding of electrical induction is explained with reference to step-and touch potential. |
ASSESSMENT CRITERION 3 |
The reason for ensuring well maintained portable earthing gear is explained according to safety standards and statutory requirements. |
ASSESSMENT CRITERION 4 |
The reason for having different types and ratings of portable earthing gear is explained according to system requirements. |
ASSESSMENT CRITERION 5 |
The consequences of not having proper earthing protection is explained according to safety standards and statutory requirements. |
SPECIFIC OUTCOME 2 |
Identify and handle portable electrical earthing gear. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The different types and ratings of portable earthing gear is identified according to application requirements. |
ASSESSMENT CRITERION 2 |
The difference between portable control and working earths is explained according to application requirements. |
ASSESSMENT CRITERION 3 |
Portable earthing gear is handled carefully and correctly to avoid possible damage. |
ASSESSMENT CRITERION 4 |
Portable earthing gear is carried, transported and stored in an approved protective bag. |
SPECIFIC OUTCOME 3 |
Inspect and care of portable earthing gear. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Portable earthing gear is visually inspected and mechanical defects are reported. |
ASSESSMENT CRITERION RANGE |
Loose or broken strands, secure connections, damaged insulation, malfunctioning clamps. |
ASSESSMENT CRITERION 2 |
Unique numbering of portable earthing gear is checked for legibility and record purposes. |
ASSESSMENT CRITERION 3 |
Portable earthing gear is cleaned according to approved methods. |
ASSESSMENT CRITERION 4 |
Portable earthing gear is stored according to approved methods. |
SPECIFIC OUTCOME 4 |
Inspect, handle and care of insulated operating rods. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Insulated operating rods are visually inspected and mechanical defects reported. |
ASSESSMENT CRITERION RANGE |
Damaged/cracked tubes, malfunctioning clamps, metal fitting, securing clips/springs. |
ASSESSMENT CRITERION 2 |
Numbering of insulated operating rods are checked for legibility and record purposes. |
ASSESSMENT CRITERION 3 |
Insulated operating rods are cleaned according to approved methods. |
ASSESSMENT CRITERION 4 |
Insulated operating rods are stored according to approved methods. |
ASSESSMENT CRITERION 5 |
Insulated operating rods are carried and transported in approved protective bags. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
Anyone assessing a learner against this unit standard must be registered as an assessor with the relevant ETQA. |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
UNIT STANDARD DEVELOPMENTAL OUTCOME |
N/A |
UNIT STANDARD LINKAGES |
N/A |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO COLLECTING |
Collect, evaluate, organise and critically evaluate information related to identifying, inspecting, handling, cleaning and storing of portable electrical earthing gear and related equipment so that these are accurately interpreted into application performance standards. |
UNIT STANDARD ASSESSOR CRITERIA |
N/A |
REREGISTRATION HISTORY |
As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. |
UNIT STANDARD NOTES |
This unit standard replaces unit standard 113868, which is "Handle and care of electrical earthing gear and related equipment", Level 2, 2 Credits. Originally re-registered on 11February 2004 under SAQA decision number 2552/04.
Supplementary Information: Specified Requirements: Specified requirements include legal and legislative specific requirements and are contained in one or more of the following documents: |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Elective | 73313 | National Certificate: Electrical Engineering | Level 2 | NQF Level 02 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | As per Learning Programmes recorded against this Qual |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
1. | 4 TOPS ACADEMY |
2. | Better Best Agri Development |
3. | BOLAND COLLEGE (Paarl) |
4. | ESKOM GENERATION - PALMIET PUMP STORAGE GRABOUW |
5. | Goitsebasadi Construction Project |
6. | In Touch Community Development & Project Managers |
7. | KP ACADEMY (PTY) LTD |
8. | MSC ARTISAN ACADEMY |
9. | PCD College cc |
10. | POWER SYSTEMS TRAINING, CAPE TOWN |
11. | Protech Training (Pty) Ltd |
12. | Umfolozi FET College |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |