All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Control slag magnetite content in a vertical converter |
SAQA US ID | UNIT STANDARD TITLE | |||
259698 | Control slag magnetite content in a vertical converter | |||
ORIGINATOR | ||||
SGB Manufacturing and Assembly Processes | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 06 - Manufacturing, Engineering and Technology | Fabrication and Extraction | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 3 | NQF Level 03 | 7 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2018-07-01 | 2023-06-30 | SAQA 06120/18 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2024-06-30 | 2027-06-30 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard replaces: |
US ID | Unit Standard Title | Pre-2009 NQF Level | NQF Level | Credits | Replacement Status |
110120 | Control slag magnetite content in a vertical converter | Level 3 | NQF Level 03 | 7 |
PURPOSE OF THE UNIT STANDARD |
This unit standard will be useful to people who are responsible for controlling slag magnetite levels in a vertical converter.
People credited with this unit standard are able to: |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
It is assumed that learners are already competent in:
|
UNIT STANDARD RANGE |
N/A |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Demonstrate knowledge relating to the controlling of magnetite. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The requirements pertaining to a safe, healthy work environment when controlling magnetite and the consequences of not adhering to the above are explained in terms of specified requirements. |
ASSESSMENT CRITERION 2 |
The importance of controlling magnetite is explained in terms of achieving specified production requirements and up-and-down stream operational requirements. |
ASSESSMENT CRITERION 3 |
Hazards and associated risks pertaining to the controlling of magnetite are identified through specified risk assessment procedures. |
ASSESSMENT CRITERION 4 |
The actions to be taken should hazards and risks be encountered are explained in terms of legal and operational requirements. |
ASSESSMENT CRITERION 5 |
The principal components of magnetite controlling system are identified and their functions explained in terms of operational requirements. |
ASSESSMENT CRITERION RANGE |
Principal components must include the following:
|
ASSESSMENT CRITERION 6 |
The actions to be taken, should sub-standard conditions and problems pertaining to magnetite controlling process be encountered, are explained in terms of operational requirements. |
ASSESSMENT CRITERION 7 |
The emergency procedures in the event of a spillage are explained in terms of legal and operational requirements. |
ASSESSMENT CRITERION 8 |
The communication requirements pertaining to the controlling of magnetite and the consequences of non-compliance are explained in terms of legal and operational requirements. |
ASSESSMENT CRITERION 9 |
The operating parameters and control methods for magnetite controlling process are explained in terms of operational requirements. |
SPECIFIC OUTCOME 2 |
Prepare to control magnetite. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Personal protective and safety equipment is verified, examined and used in accordance with specified requirements. |
ASSESSMENT CRITERION 2 |
Tools and equipment are verified and examined in accordance with operational requirements. |
ASSESSMENT CRITERION 3 |
The converter and auxiliary equipment is prepared in accordance with operational requirements. |
ASSESSMENT CRITERION 4 |
Lock-out procedures are adhered to in accordance with specified requirements. |
ASSESSMENT CRITERION 5 |
Workplace hazards and associated risks are dealt with in accordance with the relevant procedures. |
ASSESSMENT CRITERION 6 |
Magnetite controlling system are examined and substandard conditions dealt with in accordance with operational requirements. |
ASSESSMENT CRITERION 7 |
Occupational safety and health procedures towards self and others are maintained in accordance with specified requirements. |
SPECIFIC OUTCOME 3 |
Control magnetite. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Personal protective and safety equipment is used in accordance with specified requirements. |
ASSESSMENT CRITERION 2 |
The magnetite reducing process is conducted in accordance with operational requirements. |
ASSESSMENT CRITERION 3 |
The magnetite controlling process is monitored and controlled in accordance with operational requirements. |
ASSESSMENT CRITERION 4 |
Safe and optimum operation is ensured through effective communication. |
ASSESSMENT CRITERION 5 |
Tools and equipment are used in accordance with manufacturer's requirements. |
ASSESSMENT CRITERION 6 |
Work related hazards and associated risks are dealt with in accordance with specified requirements. |
ASSESSMENT CRITERION 7 |
Problems encountered are dealt with in accordance with operational requirements. |
ASSESSMENT CRITERION 8 |
Occupational safety and health procedures towards self and others are maintained in accordance with specified requirements. |
SPECIFIC OUTCOME 4 |
Complete the duties pertaining to the process of controlling magnetite. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Personal protective and safety equipment is dealt with in accordance with legal and operational requirements. |
ASSESSMENT CRITERION 2 |
Tools and equipment are dealt with in accordance with manufacturers requirements. |
ASSESSMENT CRITERION 3 |
Good housekeeping practices are maintained in accordance with specified requirements. |
ASSESSMENT CRITERION 4 |
Reports are submitted and data recorded in accordance with legal and operational requirements. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
The following embedded knowledge will be assessed in an integrated way in the context of the unit standard.
Knowledge related to preparing for maintenance in a metallurgical plant: Critical factors relating to preparing for maintenance: Processes and events: Causes and effects (Safety and Health): Procedures and techniques: Regulations, legislation, agreements, policies and standards: |
UNIT STANDARD DEVELOPMENTAL OUTCOME |
N/A |
UNIT STANDARD LINKAGES |
N/A |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO IDENTIFYING |
Identify and solve problems and make decisions using critical and creative thinking.
Note: |
UNIT STANDARD CCFO WORKING |
Work effectively with others as a member of a team, group, organisation or community.
Note: |
UNIT STANDARD CCFO COLLECTING |
Collect, analyse, organise and critically evaluate information.
Note: |
UNIT STANDARD CCFO SCIENCE |
Use science and technology effectively and critically, thus showing responsibility towards the environment and health of others.
Note: |
UNIT STANDARD CCFO DEMONSTRATING |
Demonstrate an understanding of the world as a set of related systems by recognising that problem-solving contexts do not exist in isolation.
Note: |
UNIT STANDARD ASSESSOR CRITERIA |
N/A |
REREGISTRATION HISTORY |
As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. |
UNIT STANDARD NOTES |
This unit standard replaces unit standard 110120, "Control slag magnetite content in a vertical converter", Level 3, 7 credits.
Terminology: Specified requirements include legal and site-specific requirements and are contained in one or more of the following documents: Legal: Site-Specific: > Hazard Identification and Risk Assessments (HIRA). |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Elective | 64190 | National Certificate: Metals Production | Level 3 | NQF Level 03 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | As per Learning Programmes recorded against this Qual |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |